Gust-effect factor

The gust-effect factor of ASCE/SEI 7-22 26.11. The calculation takes the natural frequency (from your analysis, or the approximate value of 26.11.3 where 26.11.2.1 permits it) and classifies the structure as rigid or flexible. It gives G = 0.85 and the computed G for rigid structures, and Gf for flexible ones (n1 < 1 Hz), with the damping ratio you enter. As an option it also gives the along-wind displacement and acceleration at the top by Commentary C26.11. It is an analysis: the result reads Calculated. Wind loads (wind_loads) covers only rigid buildings: use the factor from here in its place for a flexible one.

Inputs of the gust-effect factor

  • Wind and building:
    • The basic wind speed V (26.5) and the exposure (26.7).
    • The mean roof height h.
    • The width B normal to the wind and the depth L along it.
  • Natural frequency n1:
    • From an analysis (26.11.2), with the stiffness and mass expected under the design wind (C26.11).
    • Or the approximate lower-bound na of 26.11.3 for:
      • steel moment frames (Eq. 26.11-2);
      • concrete moment frames (Eq. 26.11-3);
      • other steel or concrete systems (Eq. 26.11-4);
      • concrete or masonry shear walls (Eq. 26.11-5, with Cw entered).
    • The approximate na is permitted only for h ≤ 300 ft and h < 4 Leff (26.11.2.1). Outside those limits the result is NOT FEASIBLE.
    • Low-rise buildings may be taken as rigid (26.11.2).
  • Damping ratio β: your judgment of the inherent damping under the design wind (C26.11, Structural Damping). The commentary example uses 1 %.
  • Rigid structures: 0.85 (26.11.1), the computed G (26.11.4), or Gf, which C26.11 permits for every case.
  • Along-wind response (C26.11):
    • Cfx, the mode shape exponent ξ and the building density (weight per volume).
    • The air density ratio.
    • A serviceability wind speed and averaging time for the acceleration.
    • An acceleration limit, if you want one: ASCE 7 sets none. A limit shows as a recommendation.

Checks performed

ItemBasis
Frequency26.11.2; Eqs. 26.11-2 to 26.11-5 with the 26.11.2.1 limits (h ≤ 300 ft, h < 4 Leff, Eq. 26.11-1)
Classification26.2: rigid where n1 ≥ 1 Hz, flexible below; low-rise permitted rigid
Rigid Gz̄ = 0.6h ≥ zmin, Iz, Lz, Q, G = 0.925(1 + 1.7 gQ Iz Q)/(1 + 1.7 gv Iz) (Eqs. 26.11-6 to -9, Table 26.11-1)
Flexible GfV̄z, N1, Rn, ηh, ηB, ηL, Rh, RB, RL, R, gR, Gf (Eqs. 26.11-10 to -16)
Along-wind responseXmax (Eq. C26.11-1), σẍ (C26.11-2, R at the service speed), gẍ (C26.11-5), ẍmax (C26.11-4)

The drawing shows a schematic elevation with the wind profile, the equivalent height 0.6h and the factor.

Limitations

  • Along-wind only. Across-wind loading, vortex shedding, galloping, flutter and torsional response are not covered (C26.11): use the literature or wind tunnel tests (26.11.6, Chapter 31).
  • One wind direction per calculation, and the fundamental mode only.
  • The acceleration limit has no basis in the code. The 1.5 to 2.5 %g in the hint is from knowledge (to confirm against the code text).
  • No auto-design: nothing is sized.

Verification examples

Verification status: 28 values compared in 5 examples (2 published, 3 hand calculations from the cited equations): 25 within tolerance, 3 recorded deviations. Thin: only 2 published examples. Code basis: the provisions it uses were read in the target edition.

ExamplePublishedILX Calcs
Table C26.11-1 (h 600 ft, Exposure B, n1 0.2 Hz, β 1 %)Iz 0.201, Lz 710 ft, Q² 0.616, V̄z 135 ft/s, N1 1.053, Rn 0.128, Rh 0.214, RB 0.666, RL 0.343, R² 1.261, gR 3.787, Gf 1.162same
Table C26.11-1, rigid G0.8600.818: Eq. 26.11-6 with the table's own Iz and Q² (recorded deviation C26.11-1-G)
Table C26.11-2K 0.501, m1 745,400 slug, V̂ 195 ft/s, Xmax 1.76 ft, V̄z 89.1 ft/s, gẍ 3.79same
Table C26.11-2, accelerationsσẍ 0.176, ẍmax 0.668 ft/s²about 0.126 and 0.48 ft/s²: the table uses R of the 115 mph case (deviation C26.11-2-SIGMA)

Hand calculations check the approximate frequencies of Eqs. 26.11-2 to 26.11-4.